Exhibition

Home > Exhibition > Content
-5 Degree Glycol Chiller Air / Water Cooled Glycol Chilling System for Dairy
Mar 29, 2017

Description:

Glycol chillers are a specific kind of refrigeration system, often used in chemical, brewery, pharmaceutical, beverage, diary industry, etc. Low temperature glycol water chiller is able to crash the temperature of the product dramatically over a short period of time, depending on the production needs.

Features:

1. Absorb heat from process water and transfer it to a separate water source, such as cooling tower, pond, river, etc.

2. Gernerally used for large capacity applications or places where a cooling tower is already in place, or where the customer requires optimum efficiency of power consumption.

3. Multi-protection devices make sure the chiller and the equipment running safety.

4. Microcomputer control unit, simple operation.

Model

MG-30WSL

MG-40WSL

MG-50WSL

MG-60WSL

MG-70WSL

MG-75WSL

MG-85WSL

MG-90WSL

MG-100WSL

MG-110WSL

Cooling Capacity

kw

55.7

76.0

99.7

108.5

132.3

145.2

171.1

180.8

197.8

214.1

Power

220V/380V/415V/460V,50HZ/60HZ; 3PHASE

Refrigerant

Type

R22, R404A

Control

Thermostatic expansion    valve

Outlet Temperature

-5℃

Compressor

Type

Semi-closed screw type

Power (kw)

21.4

28.2

35.4

38.8

47.2

51.4

57.9

60.9

67.0

68.8

Start

Y-△

Capacity

25%-50%-75%-100%

Evaporator

Type

High efficiency copper tube shell and tube type

Flow

 m³/h

9.5

13.0

17.1

18.6

22.7

24.9

29.3

31.0

33.9

36.7

Inlet/Outlet

DN50

DN65

DN80

DN80

DN80

DN80

DN100

DN100

DN100

DN100

Condenser

Type

High efficiency threaded copper tube shell and tube type

 Flow

m³/h

16.8

22.8

29.5

32.2

39.3

43.0

50.2

53.0

58.0

62.1

Inlet/Outlet

DN50

DN65

DN80

DN80

DN80

DN80

DN100

DN100

DN100

DN100

Protection    System

Compressor overheat protection, high/low pressure protection,phase missing/sequence protection,flow rate protection, anti-frozen protection.

Dimension

L

mm

2300

2300

2500

2500

2500

2800

3200

3200

3500

3500

W

mm

750

750

750

750

800

800

800

800

900

900

H

mm

1500

1500

1500

1500

1500

1500

1500

1500

1500

1800

Noise    (dB)

73.1

73.7

74.8

78.4

79.0

79.2

79.5

80.4

80.4

83.1

Weight    (kg)

660

700

800

975

1000

1150

1250

1400

1600

1750

 


Model

MG-120WSL

MG-140WSL

MG-150WSL

MG-160WSL

MG-170WSL

MG-175WSL

MG-200WSL

MG-220WSL

MG-240WSL

MG-280WSL

Cooling   Capacity

kw

235.7

280.5

296.2

324.3

351.1

364.7

424.7

466.4

498.0

561.2

Power

220V/380V/415V/460V,    50HZ/60HZ; 3PHASE

Refrigerant

Type

R22, R404A

Control

Thermostaticexpansion valve

Compressor

Type

Semi-closed screwtype

Power (kw)

81.3

88.8

93.8

108.1

109.4

120.0

138.3

153.4

162.9

183.2

Start

Y-△

Capacity

25%-50%-75%-100%

Evaporator

Type

High efficiency copper tube shell and tube type

Flow

m³/h

40.4

48.1

50.8

55.6

60.2

62.5

72.8

80.0

85.4

96.2

Inlet/Outlet

DN100

DN125

DN125

DN125

DN150

DN150

DN150

DN150

DN150

DN150

Condenser

Type

High efficiency    threaded copper tube shell and tube type

Flow

m³/h

69.5

81.1

85.7

94.8

101.3

106.4

123.6

136.0

145.0

163.4

Inlet/Outlet

DN100

DN125

DN125

DN125

DN150

DN150

DN80*2

DN100*2

DN125*2

DN125*2

Protection System

Compressor overheatprotection, high/low pressure protection,phase missing/sequence protection,flow rate protection, anti-frozen protection.

Dimension

L

mm

3500

3800

3800

3800

4000

4000

4000

4000

4000

4000

W

mm

900

900

1200

1200

1200

1200

1200

1200

1200

1200

H

mm

1800

1800

1800

1800

1800

1800

1800

1800

1800

1800

Noise (dB)

83.1

84.2

85.2

86.3

86.6

86.9

87.1

87.3

87.6

88.4

Weight (kg)

1750

1850

2000

2000

2200

2200

2400

2400

2400

2400


NOTE:

1.Normal condition:Chilled water inlet temp is 0℃,outlet temp is -5℃, ambient temp35℃;

2.Temperature condtion:Chilled water range is -5℃--15℃. This series of unit requires the chient to use the liquid with the freezing point below the required temperature as the refrigerant.

3. Allowable buctuate voltage:±10%. Allowable voltage difference in phase:±2%.

4.Actual head lift is pump head lift minus the machine internal head loss(1mH2O=9.8KPa).

5.The above parameters are based Refrigerant R22,for other parameters of refrigerant R404, please contact us.

6.Due to technology updating, size &parameters listed data may change. The above datas are for reference only,please feel free to contact us for the latest data.



3f09d73e4b01ac8c.jpg


Having been focused on top quality -5 degree glycol chiller air / water cooled glycol chilling system for dairy for over 14 years, Mgreenbelt Machinery is now one of the leading manufacturers and suppliers of various chillers in China. Our factory can also offer you customized -5 degree glycol chiller air / water cooled glycol chilling system for dairy at the best price.








Shandong Mgreenbelt Machinery Co.,LtdTel: +86-531-80960818